Frontiers in physiology · 2025
The impact of the Wingate test on anaerobic power in the lower limbs of athletes with varied duration and load.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Liu Ying, Yan Juntao, Gong Zhigang, Liu Qi
Аннотация
INTRODUCTION: This study investigates the effects of Wingate anaerobic test (WAnT) on anaerobic capacity (AC) at different duration (20, 30, 40, 45 s) and resistance load (7.5%Body Mass (BM), 8.5%BM, 9.5%BM, 10.5%BM).
METHODS: 12 male runners of 200, 400 m were subjected to four WAnT of different durations and loads. The changes of AC and lower limb muscle characteristics were analyzed by WAnT and electromyography.
RESULTS: The result shows that the integrated of electromyography (lEMG), root mean square% (RMS%), mean power frequency (MPF) and AC of lower limb muscles of rectus femoris (RF), biceps femoris (BF), vastus medialis (VM), vastus lateralis (VL), tibialis anterior (TA) and peroneus longus (PL) were increased by duration (P < 0.05 or P < 0.01), but there was no significant difference in lEMG of MG (P > 0.05). Load significantly increased AC, IEMG, RMS% and MPF of lower limb muscles (P < 0.01). The interaction effect of duration and load had no significant difference on PP, MP, IEMG, RMS% and MPF (P > 0.05), but increased on Fl (P < 0.05).
DISCUSSION: In conclusion, for 200 m and 400 m athletes, it is recommended to use a combination of 20 s and 10.5%BM load to achieve optimal peak power, as well as a combination of 20 s and 9.5%BM load for better average power. Different combinations of duration and load can be selected during the test to assess the corresponding capability.
METHODS: 12 male runners of 200, 400 m were subjected to four WAnT of different durations and loads. The changes of AC and lower limb muscle characteristics were analyzed by WAnT and electromyography.
RESULTS: The result shows that the integrated of electromyography (lEMG), root mean square% (RMS%), mean power frequency (MPF) and AC of lower limb muscles of rectus femoris (RF), biceps femoris (BF), vastus medialis (VM), vastus lateralis (VL), tibialis anterior (TA) and peroneus longus (PL) were increased by duration (P < 0.05 or P < 0.01), but there was no significant difference in lEMG of MG (P > 0.05). Load significantly increased AC, IEMG, RMS% and MPF of lower limb muscles (P < 0.01). The interaction effect of duration and load had no significant difference on PP, MP, IEMG, RMS% and MPF (P > 0.05), but increased on Fl (P < 0.05).
DISCUSSION: In conclusion, for 200 m and 400 m athletes, it is recommended to use a combination of 20 s and 10.5%BM load to achieve optimal peak power, as well as a combination of 20 s and 9.5%BM load for better average power. Different combinations of duration and load can be selected during the test to assess the corresponding capability.