BACKGROUND AND

IMPORTANCE

Stereotactic biopsies or needle aspirations of posterior fossa lesions are technically challenging. Here we report a novel technique for performing these procedures employing the Airo™ intraoperative computed tomographic (CT) scanner and the VarioGuide™ articulated arm (BrainLab, Munich, Germany).

CLINICAL PRESENTATION: A 62-yr-old woman presented with an irregularly shaped, enhancing lesion of the left pons/middle cerebellar peduncle. Slowed diffusion on magnetic resonance imaging suggested an abscess, but no definitive infectious agent/source could be identified. When the patient deteriorated despite broad-spectrum antibiotic therapy, she was taken to the operating room for stereotactic drainage of the abscess employing the described technique. A specific infectious agent (Eikenella corrodens) was identified from the aspirate, allowing for tailored antibiotic therapy. The procedure was well tolerated and the patient made a full recovery with minimal neurological sequelae.

CONCLUSION

The combination of the Airo™ intraoperative CT and the Varioguide™ articulated arm allows for safe, accurate, and efficient targeting of posterior fossa lesions.

Для цитирования: Almeida Cesar C, Uzuner Ayse, Alterman Ron L. Stereotactic Drainage of Brainstem Abscess With the BrainLab Varioguide™ System and the Airo™ Intraoperative CT Scanner: Technical Case Report.. Operative neurosurgery (Hagerstown, Md.). 2018. DOI: 10.1093/ons/opx126.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.