MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/02692155241251434

Медицинская библиотека · Clinical rehabilitation · 2024

Clinical validation of automated depth camera-based measurement of the Fugl-Meyer assessment for upper extremity.

Wang Zhaoyang, Zhang Tao, Fan Jingyuan, Gu Fanbin, Yu Qiuhua, Wang Honggang, Yang Jiantao, Zhu Qingtang

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

Depth camera-based measurement has demonstrated efficacy in automated assessment of upper limb Fugl-Meyer Assessment for paralysis rehabilitation. However, there is a lack of adequately sized studies to provide clinical support. Thus, we developed an automated system utilizing depth camera and machine learning, and assessed its feasibility and validity in a clinical setting.

DESIGN

Validation and feasibility study of a measurement instrument based on single cross-sectional data.

SETTING

Rehabilitation unit in a general hospital.

PARTICIPANTS

Ninety-five patients with hemiparesis admitted for inpatient rehabilitation unit (2021-2023).

MAIN MEASURES: Scores for each item, excluding those related to reflexes, were computed utilizing machine learning models trained on participant videos and readouts from force test devices, while the remaining reflex scores were derived through regression algorithms. Concurrent criterion validity was evaluated using sensitivity, specificity, percent agreement and Cohen's Kappa coefficient for ordinal scores of individual items, as well as correlations and intraclass correlation coefficients for total scores. Video-based manual assessment was also conducted and compared to the automated tools.

RESULT: The majority of patients completed the assessment without therapist intervention. The automated scoring models demonstrated superior validity compared to video-based manual assessment across most items. The total scores derived from the automated assessment exhibited a high coefficient of 0.960. However, the validity of force test items utilizing force sensing resistors was relatively low.

CONCLUSION

The integration of depth camera technology and machine learning models for automated Fugl-Meyer Assessment demonstrated acceptable validity and feasibility, suggesting its potential as a valuable tool in rehabilitation assessment.

Для цитирования: Wang Zhaoyang, Zhang Tao, Fan Jingyuan, Gu Fanbin, Yu Qiuhua, Wang Honggang, Yang Jiantao, Zhu Qingtang. Clinical validation of automated depth camera-based measurement of the Fugl-Meyer assessment for upper extremity.. Clinical rehabilitation. 2024. DOI: 10.1177/02692155241251434.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.