MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tnsre.2024.3379451

Медицинская библиотека · IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2024

Robust Decoding of Upper-Limb Movement Direction Under Cognitive Distraction With Invariant Patterns in Embedding Manifold.

Peng Bolin, Bi Luzheng, Wang Zhi, Feleke Aberham Genetu, Fei Weijie

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Motor brain-computer interfaces (BCIs) have gained growing research interest in motor rehabilitation, restoration, and prostheses control. Decoding upper-limb movement direction with noninvasive BCIs has been extensively investigated. However, few of them address the intervention of cognitive distraction that impairs decoding performance in practice. In this study, we propose a novel decoding model with invariant patterns in embedding manifold on a mixed dataset pooled from electroencephalograph (EEG) signals under different attentional states. We reconstruct an embedding low-dimensional manifold that intrinsically characterizes movements of the upper limb and transfer patterns of neural activities decomposed from brain functional connectivity (FC) to the manifold subspace to further preserve movement-related information. Experimental results showed that the proposed decoding model had higher robustness on the mixed dataset of attentive and distracted states compared to the baseline method. Our research provides insights into modeling a uniform underlying mechanism of movement-related EEG signals and can help enhance the practicability of BCI systems under real-world situations.

Для цитирования: Peng Bolin, Bi Luzheng, Wang Zhi, Feleke Aberham Genetu, Fei Weijie. Robust Decoding of Upper-Limb Movement Direction Under Cognitive Distraction With Invariant Patterns in Embedding Manifold.. IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society. 2024. DOI: 10.1109/tnsre.2024.3379451.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.