Experimental study for evaluation of a low-cost spray cryotherapy system.

Costa Altair da Silva, Miotto Andre, Paulo Gustavo Andrade de, Ferrari Angelo Paulo, Ota Luiz Hirotoshi

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the feasibility and applicability of a low-cost cryotherapy system.

METHODS

Experimental study with 25kg Landrace pigs submitted to a longitudinal cervico-thoraco-abdominal incision for exposure of the trachea, thorax and abdomen. The tissues were frozen by continuous spray application at different periods of time (5, 10 and 15 seconds). Spray cryotherapy was performed using a fluorinated gas (tetrafluorethane) delivered at - 47°C temperature (DermaFreeze®, Emdutos; ANVISA registration 80409950001; price R$ 394,00). via an adapted, disposable 1.8mm cholangiography catheter (Olympus; price R$ 280,00). The specimens were resected for histopathological analysis.

RESULTS

Thirty samples were obtained from ten different organs and divided according to spray cryotherapy application time. System activation for 5, 10 or 15 seconds led to consumption of 14g, 27g and 40g of gas respectively (average gas consumption, 2.7g/s using a 1.8mm catheter). The system comprising a spray tube and catheter proved user-friendly and effective, with constant gas dispersion and adequate tissue freezing. In spite of effective freezing, microscopy failed to reveal tissue changes. This may have reflected methodological constraints precluding evaluation at tissue damage peak time (48 hours).

CONCLUSION

The low-cost spray cryotherapy system proved feasible and safe.

Для цитирования: Costa Altair da Silva, Miotto Andre, Paulo Gustavo Andrade de, Ferrari Angelo Paulo, Ota Luiz Hirotoshi. Experimental study for evaluation of a low-cost spray cryotherapy system.. Einstein (Sao Paulo, Brazil). 2019. DOI: 10.31744/einstein_journal/2019ao4533.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.