MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/pd.5445

Медицинская библиотека · Prenatal diagnosis · 2019

Evaluation of a new balloon for fetal endoscopic tracheal occlusion in the nonhuman primate model.

Sananès Nicolas, Regnard Pierrick, Mottet Nicolas, Miry Claire, Fellmann Lyne, Haelewyn Laure, Delaine Maïa, Schneider Anne, Debry Christian, Favre Romain

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

We developed a new balloon called "Smart-TO," which allows noninvasive and easy unplugging, thanks to a magnetic valve actuated by the magnetic fringe field of a magnetic resonance imaging (MRI) scanner. The objective of this feasibility study was to evaluate the operation of this new balloon in a nonhuman primate model.

METHODS

Four pregnant rhesus monkeys underwent fetal endoscopic tracheal occlusion using the "Smart-TO" balloon. The pregnant monkeys were simply carried around the perimeter of an MRI scanner a few days later. Study outcomes were feasibility of fetal tracheal occlusion using the "Smart-TO" balloon, persistence of the balloon in the fetal trachea, and deflation of the balloon when subjected to the magnetic fringe field of an MRI.

RESULTS

At the time of the unplug procedure, in all cases, the balloon was still in a correct position, and its shape did not change based on their ultrasound appearance. After bringing the pregnant monkeys into the fringe field of the MRI scanner, the balloon deflated in all cases.

CONCLUSION

The balloon we developed allows noninvasive, easily triggered, and externally controlled reversal occlusion, based on the nonhuman primate model. Further tests evaluating occlusiveness and potential adverse effects are necessary.

Для цитирования: Sananès Nicolas, Regnard Pierrick, Mottet Nicolas, Miry Claire, Fellmann Lyne, Haelewyn Laure, Delaine Maïa, Schneider Anne, Debry Christian, Favre Romain. Evaluation of a new balloon for fetal endoscopic tracheal occlusion in the nonhuman primate model.. Prenatal diagnosis. 2019. DOI: 10.1002/pd.5445.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.