Shallow nasal RAE tube depth after head and neck surgery: association with preoperative and intraoperative factors.
Аннотация
PURPOSE: To evaluate risk factors associated with improper postoperative nasal Ring-Adair-Elwyn (RAE) tube depth.
METHODS
We retrospectively enrolled 133 adult patients who were admitted to the intensive care unit (ICU) with the nasal RAE tube after head and neck surgery. Postoperative chest radiography was performed to confirm nasal RAE tube depth immediately after the patient was admitted to the ICU. Proper tube depth was defined as the tube tip between 2 and 7 cm above the carina. The patients were divided into the proper-depth group (78 patients) and the improper-depth group (55 patients). Patients' characteristics were collected. The risk factors for improper postoperative tube depth were assessed using logistic regression analysis.
MAIN
RESULTS
All patients who showed improper tube depth had a shallow tube depth (the tube tip > 7 cm above the carina). Multivariable analysis revealed that tall stature [odds ratio (OR) 1.16; 95% confidence interval (CI) 1.08-1.25; P < 0.001], prolonged anesthesia duration (OR 1.16; 95% CI 1.02-1.32; P = 0.026), and right-sided surgical field as compared to the left (OR 0.36; 95% CI 0.14-0.93; P = 0.034) or median field (OR 0.25; 95% CI 0.07-0.85; P = 0.027) were risk factors associated with postoperative shallow tube depth.
CONCLUSIONS
Tall stature, prolonged anesthesia duration, and right-sided surgical field were independent risk factors for postoperative shallow nasal RAE tube depth.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.