m+Medelevator.RU
← Поиск публикаций
Annals of surgical oncology · 2021

Vacuum-Assisted Breast Biopsy After Neoadjuvant Systemic Treatment for Reliable Exclusion of Residual Cancer in Breast Cancer Patients.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Koelbel Vivian, Pfob André, Schaefgen Benedikt, Sinn Peter, Feisst Manuel, Golatta Michael, Gomez Christina, Stieber Anne, Bach Paul, Rauch Geraldine, Heil Joerg

Аннотация

BACKGROUND: About 40 % of women with breast cancer achieve a pathologic complete response in the breast after neoadjuvant systemic treatment (NST). To identify these women, vacuum-assisted biopsy (VAB) was evaluated to facilitate risk-adaptive surgery. In confirmatory trials, the rates of missed residual cancer [false-negative rates (FNRs)] were unacceptably high (> 10%). This analysis aimed to improve the ability of VAB to exclude residual cancer in the breast reliably by identifying key characteristics of false-negative cases.

METHODS: Uni- and multivariable logistic regressions were performed using data of a prospective multicenter trial (n = 398) to identify patient and VAB characteristics associated with false-negative cases (no residual cancer in the VAB but in the surgical specimen). Based on these findings FNR was exploratively re-calculated.

RESULTS: In the multivariable analysis, a false-negative VAB result was significantly associated with accompanying ductal carcinoma in situ (DCIS) in the initial diagnostic biopsy [odds ratio (OR), 3.94; p < 0.001], multicentric disease on imaging before NST (OR, 2.74; p = 0.066), and age (OR, 1.03; p = 0.034). Exclusion of women with DCIS or multicentric disease (n = 114) and classication of VABs that did not remove the clip marker as uncertain representative VABs decreased the FNR to 2.9% (3/104).

CONCLUSION: For patients without accompanying DCIS or multicentric disease, performing a distinct representative VAB (i.e., removing a well-placed clip marker) after NST suggests that VAB might reliably exclude residual cancer in the breast without surgery. This evidence will inform the design of future trials evaluating risk-adaptive surgery for exceptional responders to NST.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты