The Feasibility of an Experimental Hypobaric Simulation to Evaluate the Safety of Closed-Loop Insulin Delivery Systems in Flight-Related Atmospheric Pressure Changes.

Fan Ka Siu, Shojaee-Moradie Fariba, Manoli Antonios, Baumann Petra M, Koehler Gerd, Edwards Victoria, Lee Vivienne, Mathieu Chantal, Mader Julia K, Russell-Jones David, EASA Diabetes Consortium

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Hybrid closed-loop (HCL) systems remain underexplored within aviation, and as atmospheric pressure changes can independently affect insulin pumps and continuous glucose monitoring readings, this preliminary study assessed the feasibility of HCL safety evaluation, in both fasting and post-prandial states, by using hypobaric chamber to simulate flights. Participants with type 1 diabetes and on HCL were studied: Medtronic Guardian 4-Medtronic 780G-SmartGuard (n = 4), Dexcom G6-Omnipod DASH-Android APS (n = 1), and Dexcom G6-Ypsomed Pump-CamAPS (n = 1). Flight cabin pressures of 550 mmHg and 750 mmHg were simulated in a hypobaric chamber. Seven-hundred-50 glucose measurements were taken, with glucose levels demonstrating a stable decline to 4 mmol/L during fasting. To maintain a tight fasting and post-prandial glucose range across the different pressure settings, the HCL administered insulin as expected. While not demonstrating any apparent issues, repeating flight simulation protocol with other systems, examining longer flights, and undertaking larger, powered randomised controlled trials can confirm their safety in aviation.

Для цитирования: Fan Ka Siu, Shojaee-Moradie Fariba, Manoli Antonios, Baumann Petra M, Koehler Gerd, Edwards Victoria, Lee Vivienne, Mathieu Chantal, Mader Julia K, Russell-Jones David, EASA Diabetes Consortium. The Feasibility of an Experimental Hypobaric Simulation to Evaluate the Safety of Closed-Loop Insulin Delivery Systems in Flight-Related Atmospheric Pressure Changes.. Diabetes technology & therapeutics. 2024. DOI: 10.1089/dia.2024.0380.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.