BACKGROUND

Augmented Reality (AR) is a technology that can allow a surgeon to see subsurface structures. This works by overlaying information from another modality, such as MRI and fusing it in real time with the endoscopic images. AR has never been developed for a very mobile organ like the uterus and has never been performed for gynecology. Myomas are not always easy to localize in laparoscopic surgery when they do not significantly change the surface of the uterus, or are at multiple locations.

OBJECTIVE

To study the accuracy of myoma localization using a new AR system compared to MRI-only localization.

METHODS

Ten residents were asked to localize six myomas (on a uterine model into a laparoscopic box) when either using AR or in conditions that simulate a standard method (only the MRI was available). Myomas were randomly divided in two groups: the control group (MRI only, AR not activated) and the AR group (AR activated). Software was used to automatically measure the distance between the point of contact on the uterine surface and the myoma. We compared these distances to the true shortest distance to obtain accuracy measures. The time taken to perform the task was measured, and an assessment of the complexity was performed.

RESULTS

The mean accuracy in the control group was 16.80 mm [0.1-52.2] versus 0.64 mm [0.01-4.71] with AR. In the control group, the mean time to perform the task was 18.68 [6.4-47.1] s compared to 19.6 [3.9-77.5] s with AR. The mean score of difficulty (evaluated for each myoma) was 2.36 [1-4] versus 0.87 [0-4], respectively, for the control and the AR group.

DISCUSSION: We developed an AR system for a very mobile organ. This is the first user study to quantitatively evaluate an AR system for improving a surgical task. In our model, AR improves localization accuracy.

Для цитирования: Bourdel Nicolas, Collins Toby, Pizarro Daniel, Bartoli Adrien, Da Ines David, Perreira Bruno, Canis Michel. Augmented reality in gynecologic surgery: evaluation of potential benefits for myomectomy in an experimental uterine model.. Surgical endoscopy. 2016. DOI: 10.1007/s00464-016-4932-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.