MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.contraception.2012.01.005

Медицинская библиотека · Contraception · 2012

Intracervical lidocaine gel for intrauterine device insertion: a randomized controlled trial.

Maguire Karla, Davis Anne, Rosario Tejeda Linette, Westhoff Carolyn

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Pain during intrauterine device (IUD) insertion can be a barrier to initiation. Clinical trials have found misoprostol and nonsteroidal drugs to be ineffective (Am J Obstet Gynecol 2006;195:1272-1277, Hum Reprod 2011;26:323-329, Hum Reprod 2007;22:2647-2652). One study suggested that 2% lidocaine gel decreased pain; however, study design problems limit its validity (Brit J Fam Plann 1996;22:177-180). We tested whether intracervical 2% lidocaine gel decreased insertion pain compared to placebo.

STUDY

DESIGN

We planned a randomized, double-blinded clinical trial of 200 women. We placed 2% lidocaine gel or placebo in the cervix prior to uterine sounding. Participants rated pain by marking a 100-mm visual analogue scale at four time points.

RESULTS

We randomized 200 participants and placed 197 IUDs. Pain was greatest at uterine sounding and similar between groups: placebo group mean 51.6 mm (SD 25), lidocaine group mean 55.5 mm (SD 30, p=.33). Stratified analyses accounting for parity showed no treatment effect. Multivariable analyses identified longer time since last pregnancy, lower parity and higher anticipated pain as predictors of pain during sounding, and dysmenorrhea and the levonorgestrel IUD as additional predictors during IUD insertion.

CONCLUSIONS

Intracervical 2% lidocaine gel does not decrease IUD insertion pain. Understanding predictors of increased pain may help providers with preprocedure counseling.

Для цитирования: Maguire Karla, Davis Anne, Rosario Tejeda Linette, Westhoff Carolyn. Intracervical lidocaine gel for intrauterine device insertion: a randomized controlled trial.. Contraception. 2012. DOI: 10.1016/j.contraception.2012.01.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.