MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/14767058.2012.657278

Медицинская библиотека · The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians · 2012

Transabdominal evaluation of uterine cervical length during pregnancy fails to identify a substantial number of women with a short cervix.

Hernandez-Andrade Edgar, Romero Roberto, Ahn Hyunyoung, Hussein Youssef, Yeo Lami, Korzeniewski Steven J, Chaiworapongsa Tinnakorn, Hassan Sonia S

Сравнительное исследованиеОценочное исследованиеСтатьяResearch Support, N.I.H., IntramuralПеревод пока не подготовлен

Аннотация

OBJECTIVE

To assess the diagnostic performance of transabdominal sonographic measurement of cervical length in identifying patients with a short cervix.

METHODS

Cervical length was measured in 220 pregnant women using transabdominal and transvaginal ultrasound (US). Reproducibility and agreement between and within both methods were assessed. The diagnostic accuracy of transabdominal US for identifying cases with a cervical length <25 mm was evaluated.

RESULTS

Twenty-one out of 220 cases (9.5%) had a cervical length <25 mm by transvaginal US. Only 43% (n = 9) of patients with a short cervix were correctly identified by transabdominal US. In patients with a cervical length of <25 mm by transvaginal US, transabdominal measurement of the cervix overestimated this parameter by an average of 8 mm (95% LOAs, -26.4 to 10.5 mm). Among women without a short cervix, transabdominal US underestimated cervical length on average (LOA) by 1.1 mm (95% LOAs, -11.0 to 13.2 mm). Transvaginal US was also more reproducible (intraclass correlation coefficient: (ICC) (0.96; 95% CI, 0.94 to 0.97) based on comparisons between 2D images and immediately acquired 3D volume datasets relative to transabdominal US (ICC: 0.71; 95% CI, 0.57 to 0.84). Transvaginal US detected 13 cases with funneling and six cases with sludge whereas only three cases of funneling and one of sludge were detected by transabdominal US.

CONCLUSION

Transabdominal measurement overestimated cervical LOA by 8 mm among women with a short cervix and resulted in the underdiagnosis of 57% of cases.

Для цитирования: Hernandez-Andrade Edgar, Romero Roberto, Ahn Hyunyoung, Hussein Youssef, Yeo Lami, Korzeniewski Steven J, Chaiworapongsa Tinnakorn, Hassan Sonia S. Transabdominal evaluation of uterine cervical length during pregnancy fails to identify a substantial number of women with a short cervix.. The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians. 2012. DOI: 10.3109/14767058.2012.657278.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.