DOI 10.3390/biomedicines13081920
Paired-Pulse Repetitive Trans-Spinal Magnetic Stimulation Supports Balance Ability While the Coil Orientation Significantly Determines the Effects: A Randomised, Placebo-Controlled Trial.
Аннотация
Objectives
The primary objective was to investigate and compare the effects of three paired-pulse repetitive trans-spinal magnetic stimulation (PP-rTSMS) protocols on balance control and corticospinal network function.
Methods
PP-rTSMS (800 pulses, frequency 100 Hz, intensity 70% of the resting motor threshold) was applied over the eighth thoracic vertebra (Th8) in twenty-seven young healthy individuals. Each proband received three verum sessions (using a verum coil with handle oriented (i) cranially, (ii) caudally, and (iii) laterally) and (iv) one sham session (using a sham coil) in a randomised order. Balance ability (Y Balance Test) and corticospinal network functions (motor evoked potentials (MEPs), cortical silent periods (SCPs)) were tested immediately (i) prior to and (ii) after each interventional session.
Results
Each verum session induced a significant improvement in balance ability (cranially (F1,26 = 8.009; p = 0.009; η2 = 0.236), caudally (F1,26 = 4.846; p = 0.037; η2 = 0.157), and laterally (F1,26 = 23,804; p ≤ 0.001; η2 = 0.478) oriented grip) as compared to the sham session. In addition, the laterally oriented coil grip was associated with significantly greater balance benefits than both the cranial (F1,26 = 10.173; p = 0.004; η2 = 0.281) and caudal (F1,26 = 14.058; p ≤ 0.001; η2 = 0.351) grip orientations. No significant intervention-induced effects were detected on corticospinal network functions.
Conclusions
Our data show that PP-rTSMS effectively supports balance control and that coil orientation significantly influences these effects. Further studies should test variations of this promising approach on healthy and disabled cohorts.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.