MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/opx.0b013e318294c184

Медицинская библиотека · Optometry and vision science : official publication of the American Academy of Optometry · 2013

In vivo confocal evaluation of the ocular surface morpho-functional unit in dry eye.

Villani Edoardo, Magnani Fabrizio, Viola Francesco, Santaniello Alessandro, Scorza Raffaella, Nucci Paolo, Ratiglia Roberto

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To study, by a new, integrated, laser scanning confocal microscopy approach, the ocular surface morpho-functional unit in patients with primary Sjogren syndrome (SSI), non-Sjogren syndrome dry eye (non-SSDE), and meibomian gland disease (MGD).

METHODS

Patients and age- and sex-matched control subjects (N = 60; 15 each) were consecutively enrolled in a prospective case-control study. Laser scanning confocal microscopy was used to obtain simultaneous optical sampling of the ocular surface components: cornea, bulbar and tarsal conjunctiva, MGs, and eyelid margin.

RESULTS

For all superficial epithelia, except eyelid margins, there were reduced cell densities in each group compared with that in controls (p < 0.001). The lowest cell densities were in the SSI group (p < 0.001). Eyelid margin superficial cell density was decreased only in MGD (p < 0.001). Basal epithelial cell density at the corneal apex was increased in both SSI and non-SSDE compared with that in controls (p < 0.01). In the conjunctiva, it was decreased in each group compared with that in controls (p < 0.01). Subbasal dendritic cell density was significantly increased in both SSI and MGD compared with that in controls (p < 0.01). Conjunctival inflammatory cell density and MG inflammation were increased in each group compared with those in controls (p < 0.001), with the highest values in SSI. Subbasal nerve plexi had fewer fibers and higher bead density in each group compared with those in controls (p < 0.001). There was increased tortuosity in both SSI and MGD (p < 0.001). Patients with MGD had the lowest MG acinar density, the largest diameter of acini and acinar orifices, and the highest secretion reflectivity (p < 0.001).

CONCLUSIONS

Laser scanning confocal microscopy can provide an in vivo, noninvasive, high-resolution overview of the ocular surface morpho-functional unit. This confocal integrated approach may be useful in both research and clinical settings.

Для цитирования: Villani Edoardo, Magnani Fabrizio, Viola Francesco, Santaniello Alessandro, Scorza Raffaella, Nucci Paolo, Ratiglia Roberto. In vivo confocal evaluation of the ocular surface morpho-functional unit in dry eye.. Optometry and vision science : official publication of the American Academy of Optometry. 2013. DOI: 10.1097/opx.0b013e318294c184.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.