MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/iae.0b013e3182877585

Медицинская библиотека · Retina (Philadelphia, Pa.) · 2013

Povidone-iodine contact time and lid speculum use during intravitreal injection.

Friedman Duncan A, Mason John O, Emond Tracy, McGwin Gerald

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the time necessary for 5% povidone-iodine (PI) to cause a significant reduction in colony-forming units and whether a lid speculum increases the conjunctival flora.

METHODS

This was a prospective randomized study of 131 eyes undergoing intravitreal injection. Conjunctival samples were collected in a prospective protocol at three points before intravitreal injection: (1) no intervention (baseline), (2) after placement of a lid speculum, and (3) after treatment with 5% PI. Participants were randomized into three different PI exposure intervals. Cultures were incubated for 6 days, and the resulting colony-forming units were tallied for each intervention.

RESULTS

Use of 5% PI caused significant decrease in the number of colony-forming units (P < 0.0001). Exposure to PI for 15 seconds did not cause a significant reduction in conjunctival bacteria (P = 0.08), but a significant reduction was observed after 30 seconds of exposure and beyond (P = 0.0003). Placement of a lid speculum did not result in a significant increase or decrease in the number of colony-forming units when compared with baseline (P = 0.47).

CONCLUSION

The use of 5% PI causes a significant reduction in bacterial colonies, and 30 seconds of exposure appears to be an adequate time to decrease conjunctival bacterial counts. Lid speculum use before intravitreal injection does not affect the overall conjunctival flora.

Для цитирования: Friedman Duncan A, Mason John O, Emond Tracy, McGwin Gerald. Povidone-iodine contact time and lid speculum use during intravitreal injection.. Retina (Philadelphia, Pa.). 2013. DOI: 10.1097/iae.0b013e3182877585.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.