MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000544958

Медицинская библиотека · Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde · 2025

Geographic Atrophy and Peripheral Atrophy: Quantitative Analysis with Ultra-Widefield Autofluorescence.

De Geronimo Daniele, Parravano Mariacristina, Sacconi Riccardo, Costanzo Eliana, Varano Monica, Querques Giuseppe

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

To analyze and correlate the topographic distribution of atrophic areas at the posterior pole and peripheral retina in subjects with geographic atrophy (GA) using ultra-widefield fundus autofluorescence (FAF) imaging.

METHODS

This multicenter observational study included 15 patients (9 males, 19 eyes) with coexisting GA and peripheral atrophy. All eyes were imaged with Ultra-widefield Optos California (Optos, PLC, Dunfermline, Scotland) to acquire ultra-widefield (200°) color and FAF images centered on the fovea, superior, inferior, nasal, and temporal sectors. The extent of GA in the central FAF image and the peripheral atrophic areas in the peripheral FAF images were measured by manually defining the boundaries of the atrophic regions using the "ROI free" function integrated into the device software. The values obtained were then analyzed and correlated.

RESULTS

The mean ± standard deviation (SD) GA size was 13.9 ± 15.0 mm2 (range: 1.8-71.3 mm2) and the total peripheral atrophy was 51.0 ± 68.3 mm2 (range: 1.4-292.1 mm2). The topographic analysis showed that the mean ± SD of superior peripheral atrophy was 9.0 ± 20.6 mm2, temporal atrophy was 30.5 ± 55.9 mm2, inferior atrophy was 9.3 ± 16.3 mm2, and nasal atrophy was 1.8 ± 3.9 mm2. GA size was significantly correlated with total peripheral atrophy (Rho = 0.463, p = 0.046) and temporal peripheral atrophy (Rho = 0.474, p = 0.040), whereas no correlations were found with peripheral atrophy in the remaining sectors.

CONCLUSION

Ultra-widefield autofluorescence is a valuable technique for visualizing and assessing the extent of macular and peripheral atrophy. Macular atrophy correlates significantly with total and temporal peripheral atrophy but demonstrates no significant correlation with atrophy in the remaining sectors.

Для цитирования: De Geronimo Daniele, Parravano Mariacristina, Sacconi Riccardo, Costanzo Eliana, Varano Monica, Querques Giuseppe. Geographic Atrophy and Peripheral Atrophy: Quantitative Analysis with Ultra-Widefield Autofluorescence.. Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde. 2025. DOI: 10.1159/000544958.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.