m+Medelevator.RU
← Поиск публикаций
Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2025

The current practice of volumetric modulated arc therapy for breast cancer in Europe - A survey by the EFOMP VMAT breast working group.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Koivumäki T, Clivio A, Doolan P, Essers M, Fusella M, Jäckel M, Laugaard Lorenzen E, Lizondo M, Noblet C, EFOMP VMAT Breast working group collaborators

Аннотация

INTRODUCTION: VMAT is used in the treatment of breast cancer with a wide variety of approaches. The objective of this study is to identify and share the most common indications, techniques, and practices for the use of VMAT for breast irradiation.

METHODS: The EFOMP VMAT Breast working group conducted an online questionnaire for European medical physicists via EFOMP national member organizations in February-March 2024. The questionnaire consisted of 56 questions in six categories: background of responders; treatment site specific approaches; dosimetric principles; treatment planning; quality assurance; and foundation of the VMAT breast technique used.

RESULTS: A total of 314 responses were analyzed from various institutes across 31 countries, representing approximately 20 % of European radiotherapy centers. Of these, 73 % use VMAT for breast radiotherapy. Among the VMAT users, VMAT is most often used for more complex treatment sites, such as breast with lymph nodes and the internal mammary chain (56 % of responders). Most of these treatments are performed with C-arm linacs (77 %), using daily IGRT (>80 % of institutes) with CBCT (>50 %) as the preferred technique. Across all treatment sites, VMAT breast treatments are most often implemented with two arcs, an arc length of >150°, 5 mm CTV-to-PTV margin and skin/auto flash of 10 mm.

CONCLUSION: This paper presents a comprehensive survey of VMAT breast radiotherapy in Europe. These data can serve as a useful reference point or starting guide for centers establishing VMAT protocols.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты