Single-energy metal artifact reduction for helical computed tomography of the pelvis in patients with metal hip prostheses.

Yasaka Koichiro, Maeda Eriko, Hanaoka Shouhei, Katsura Masaki, Sato Jiro, Ohtomo Kuni

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the quality of helical computed tomography (CT) images of the pelvis in patients with metal hip prostheses reconstructed using adaptive iterative dose reduction (AIDR) and AIDR with single-energy metal artifact reduction (SEMAR-A).

MATERIALS AND

METHODS

This retrospective study included 28 patients (mean age, 64.6 ± 11.4 years; 6 men and 22 women). CT images were reconstructed using AIDR and SEMAR-A. Two radiologists evaluated the extent of metal artifacts and the depiction of structures in the pelvic region and looked for mass lesions. A radiologist placed a region of interest within the bladder and recorded CT attenuation.

RESULTS

The metal artifacts were significantly reduced in SEMAR-A as compared to AIDR (p < 0.0001). The depictions of the bladder, ureter, prostate/uterus, rectum, and pelvic sidewall were significantly better with SEMAR-A than with AIDR (p < 0.02). All lesions were diagnosed with SEMAR-A, while some were not diagnosed with AIDR. The median and interquartile range (in parentheses) of CT attenuation within the bladder for AIDR were -34.0 (-46.6 to -15.0) Hounsfield units (HU) and were more variable than those seen for SEMAR-A [5.4 (-1.3 to 11.1)] HU (p = 0.033).

CONCLUSION

In comparison with AIDR, SEMAR-A provided pelvic CT images of significantly better quality for patients with metal hip prostheses.

Для цитирования: Yasaka Koichiro, Maeda Eriko, Hanaoka Shouhei, Katsura Masaki, Sato Jiro, Ohtomo Kuni. Single-energy metal artifact reduction for helical computed tomography of the pelvis in patients with metal hip prostheses.. Japanese journal of radiology. 2016. DOI: 10.1007/s11604-016-0566-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.