MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00261-016-0915-4

Медицинская библиотека · Abdominal radiology (New York) · 2017

Diagnostic performance of 18-F-FDG-PET-CT in adrenal lesions using histopathology as reference standard.

Altinmakas Emre, Hobbs Brian P, Ye Hui, Grubbs Elizabeth G, Perrier Nancy D, Prieto Victor G, Lee Jeffrey E, Ng Chaan S

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the diagnostic performance of PET-CT in differentiating benign and malignant adrenal lesions when evaluating PET parameters individually as well as in combination with CT parameters, using histopathology as the reference standard.

METHODS

18F-FDG-PET-CT scans of patients undertaken within 6 months prior to pathologic evaluation of their adrenal lesion(s) were evaluated. PET assessments consisted individually of maximum standardized uptake value of the adrenal lesion (A-SUVmax) and its ("normalized") ratio to the liver (R-SUVmax). The diagnostic performances of these two PET parameters were also assessed when combined with the Hounsfield density from the non-contrast CT component of the PET-CT (A-HU). Diagnostic performance was assessed by area under the curve (AUC) of the receiver operating characteristics. Multiple logistic regression analysis was used to evaluate the individual and combined parameters.

RESULTS

The study cohort consisted of 61 adrenal lesions (59 patients). Malignant lesions (n = 52) had significantly higher median PET and CT parameters than benign lesions: A-SUVmax (11.4 vs. 6.1), R-SUVmax (3.3 vs. 1.7), and A-HU (37 vs. 24) [all p < 0.023]. AUC for the PET parameters individually was almost identical: 0.75 for A-SUVmax and 0.74 for R-SUVmax. On univariate analysis, thresholds of A-SUVmax >3.47 and R-SUVmax >0.83 yielded maximum accuracy (both 87%). The combination of these PET parameters individually with A-HU improved both AUC and accuracy (0.81% and 93%, respectively).

CONCLUSIONS

The individual PET parameters A-SUVmax and R-SUVmax have similar diagnostic performance for differentiating malignant and benign adrenal lesions; their performance and accuracy improve when combined with the CT component (A-HU).

Для цитирования: Altinmakas Emre, Hobbs Brian P, Ye Hui, Grubbs Elizabeth G, Perrier Nancy D, Prieto Victor G, Lee Jeffrey E, Ng Chaan S. Diagnostic performance of 18-F-FDG-PET-CT in adrenal lesions using histopathology as reference standard.. Abdominal radiology (New York). 2017. DOI: 10.1007/s00261-016-0915-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.