MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ndt/gfr393

Медицинская библиотека · Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association · 2011

Low pleural fluid-to-serum glucose gradient indicates pleuroperitoneal communication in peritoneal dialysis patients: presentation of two cases and a review of the literature.

Momenin Nima, Colletti Patrick M, Kaptein Elaine M

Клинический случайСтатьяОбзорПеревод пока не подготовлен

Аннотация

BACKGROUND

Transudative pleural effusions due to pleuroperitoneal communication occur in 1.6-10% of patients receiving peritoneal dialysis (PD) and usually have overtly elevated glucose concentrations.

METHODS

We report two cases of verified pleuroperitoneal communication with minimally elevated pleural fluid glucose levels. We reviewed the literature of all PD patients with pleuroperitoneal communication that reported pleural glucose levels to assess their clinical and laboratory features and pleural fluid-to-serum glucose gradients.

RESULTS

We evaluated a total of 47 reported patients on PD with diagnosed pleuroperitoneal communication. Onset of the transudative pleural effusion after initiating PD was <3 months in only 48%. Shortness of breath was reported in 96%. Pleural effusions were right sided in 87%. Pleural fluid-to-serum glucose gradients varied from 2 to 1885 mg/dL, with 20% ≤50 mg/dL, 13% being 51-100 and 67% >100 mg/dL. All pleural fluid-to-serum glucose ratios were >1.

CONCLUSIONS

With a transudative pleural effusion in patients receiving PD, a pleural fluid-to-serum glucose ratio >1 is consistent with a pleuroperitoneal communication. In questionable cases, independent verification is necessary.

Для цитирования: Momenin Nima, Colletti Patrick M, Kaptein Elaine M. Low pleural fluid-to-serum glucose gradient indicates pleuroperitoneal communication in peritoneal dialysis patients: presentation of two cases and a review of the literature.. Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association. 2011. DOI: 10.1093/ndt/gfr393.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.