DOI 10.1016/j.dld.2019.06.008

Медицинская библиотека · Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver · 2019

Capsule endoscopy: Is the software TOP 100 a reliable tool in suspected small bowel bleeding?

Arieira Cátia, Monteiro Sara, Dias de Castro Francisca, Boal Carvalho Pedro, Rosa Bruno, Moreira Maria João, Cotter José

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Small bowel capsule endoscopy (SBCE) is the reference standard tool for diagnosing small bowel bleeding (SBB). The "TOP 100", which performs an automatic selection of the 100 images that mostly likely contain abnormalities, emerged as a new functionality of the RAPID Reader® software in 2017.

AIM: To compare the concordance of findings between the standard reading (SR) and the use of TOP 100 in suspected SBB.

METHODS

Retrospective study, including consecutive patients submitted to SBCE for suspected SBB. Two experienced readers performed SR and reported the most important findings. Another experienced reader, who was blinded to the SR results, reviewed all the SBCE videos using TOP 100 and reported the most important findings. The relevant findings were defined as the presence of high bleeding potential lesions (P2).

RESULTS

97 patients were included. The TOP 100 detected 81/97(83.5%) of the P2 lesions, in particular 64/67(95.5%) of the angioectasias and 17/30(56.7%) of the ulcers. The TOP 100 identified all sites of active bleeding (n = 9).

CONCLUSION

The TOP 100 identified all sites of active bleeding, as well as the vast majority of significant lesions (83.5%); in particular, it detected over 95% of the angioectasias. Although SR remains the reference standard in the SBCE review, these findings demonstrate that TOP 100 allows for a quick preview reading constituting an important asset in the identification of lesions that may require priority full review and intervention planning.

Для цитирования: Arieira Cátia, Monteiro Sara, Dias de Castro Francisca, Boal Carvalho Pedro, Rosa Bruno, Moreira Maria João, Cotter José. Capsule endoscopy: Is the software TOP 100 a reliable tool in suspected small bowel bleeding?. Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver. 2019. DOI: 10.1016/j.dld.2019.06.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.