BACKGROUND

Video-assisted transthoracic surgery (VATS) is a minimally invasive procedure that has been reported as a valid method for tracheal resection and reconstruction. However, for patients with tracheal tumors, one-lung ventilation during VATS is difficult to achieve, and utilizing a double-lumen tube is not applicable in these types of situations. When using a bronchial blocker, a fiberoptic bronchoscope is required to verify the position of bronchial blocker, though the repeated use of the fiberoptic bronchoscope increases the risk of tumor rupture and hemorrhage.

CASE PRESENTATION: We report a case with a middle tracheal tumor received tracheal resection and reconstruction under VATS, in which VivaSight™ single-lumen tube guided bronchial blocker placement was used for achieving one-lung ventilation. The VivaSight™ single-lumen tube can provide real-time and continuous monitoring of the position of bronchial blocker. Moreover, it does not require the aid of fiberoptic bronchoscopy.

CONCLUSIONS

VivaSight™ single-lumen tube combined with a bronchial blocker is a feasible choice for one-lung ventilation in this type of surgery.

Для цитирования: Qiu Jin, Feng Miaomiao, Zhang Chuanhan, Yao Wenlong. VivaSight™ single-lumen tube guided bronchial blocker placement for one-lung ventilation in a patient with a tracheal tumor under video-assisted transthoracic surgery: a case report.. BMC anesthesiology. 2019. DOI: 10.1186/s12871-018-0677-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.