MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11095-018-2542-y

Медицинская библиотека · Pharmaceutical research · 2018

Delivery of pDNA Polyplexes to Bronchial and Alveolar Epithelial Cells Using a Mesh Nebulizer.

Gomes Dos Reis Larissa, Svolos Maree, Moir Lyn M, Jaber Rima, Windhab Norbert, Young Paul M, Traini Daniela

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: In this study, a cell penetrating peptide was used as an uptake enhancer for pDNA delivery to the lungs.

METHODS

Polyplexes were prepared between pDNA and CPP. Intracellular delivery of pDNA was assessed in both alveolar (A549) and bronchial (Calu-3) epithelial cells. Aerosol delivery was investigated using a mesh nebulizer.

RESULTS

Efficient intracellular delivery of pDNA occurs in both A549 and Calu-3 cells when delivered as polyplexes. Protection against nucleases and endosomal escape mechanism occurs when pDNA is formulated within the polyplexes. For aerosol delivery, 1% (w/v) mannitol was able to protect naked DNA structure during nebulization with a significant increase in fine particle fraction (particles <5 μm). The structure of polyplexes when delivered via a mesh nebulizer using 1% (w/v) mannitol could partially withstand the shear forces involved in aerosolization. Although some loss in functionality occurred after nebulization, membrane-associated fluorescence was observed in A549 cells. In Calu-3 cells mucus entrapment was a limiting factor for polyplex delivery.

CONCLUSIONS

The presence of CPP is essential for efficient intracellular delivery of pDNA. The polyplexes can be delivered to lung epithelial cells using mesh nebulizer. The use of different excipients is essential for further optimization of these delivery systems.

Для цитирования: Gomes Dos Reis Larissa, Svolos Maree, Moir Lyn M, Jaber Rima, Windhab Norbert, Young Paul M, Traini Daniela. Delivery of pDNA Polyplexes to Bronchial and Alveolar Epithelial Cells Using a Mesh Nebulizer.. Pharmaceutical research. 2018. DOI: 10.1007/s11095-018-2542-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.