MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/medicina55070394

Медицинская библиотека · Medicina (Kaunas, Lithuania) · 2019

The Influence of Bowel Preparation on ADC Measurements: Comparison between Conventional DWI and DWIBS Sequences.

Apine Ilze, Baduna Monta, Pitura Reinis, Pokrotnieks Juris, Krumina Gaida

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

Background and objectives: The aim of the study was to assess whether there were differences between apparent diffusion coefficient (ADC) values of diffusion-weighted imaging (DWI) and diffusion-weighted imaging with background body signal suppression (DWIBS) sequences in non-prepared and prepared bowels before and after preparation with an enteric hyperosmolar agent, to assess whether ADC measurements have the potential to avoid bowel preparation and whether ADC-DWIBS has advantages over ADC-DWI. Materials and

Methods

106 adult patients without evidence of inflammatory bowel disease (IBD) underwent magnetic resonance (MR) enterography before and after bowel preparation. ADC-DWI and ADC-DWIBS values were measured in the intestinal and colonic walls demonstrating high signal intensity (SI) at DWI tracking images of b = 800 s/mm2 before and after preparation.

Results

There were significant difference (p < 0.0001) in both ADC-DWI and ADC-DWIBS results between non-prepared and prepared jejunum for DWI being 1.09 × 10-3 mm2/s and 1.76 × 10-3 mm2/s, respectively, and for DWIBS being 0.91 × 10-3 mm2/s and 1.75 × 10-3 mm2/s, respectively. Both ADC-DWI and DWIBS also showed significant difference between non-prepared and prepared colon (p < 0.0001), with DWI values 1.41 × 10-3 mm2/s and 2.13 × 10-3 mm2/s, and DWIBS-1.01 × 10-3 mm2/s and 2.04 × 10-3 mm2/s, respectively. No significant difference between ADC-DWI and ADC-DWIBS was found in prepared jejunum (p = 0.84) and prepared colon (p = 0.58), whereas a significant difference was found in non-prepared jejunum and non-prepared colon (p = 0.0001 in both samples).

Conclusions

ADC between DWI and DWIBS does not differ in prepared bowel walls but demonstrates a difference in non-prepared bowel. ADC in non-prepared bowel is lower than in prepared bowel and possible overlap with the ADC range of IBD is possible in non-prepared bowel. ADC-DWIBS has no advantage over ADC-DWI in regard to IBD assessment.

Для цитирования: Apine Ilze, Baduna Monta, Pitura Reinis, Pokrotnieks Juris, Krumina Gaida. The Influence of Bowel Preparation on ADC Measurements: Comparison between Conventional DWI and DWIBS Sequences.. Medicina (Kaunas, Lithuania). 2019. DOI: 10.3390/medicina55070394.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.