MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13054-023-04738-6

Медицинская библиотека · Critical care (London, England) · 2023

Myocardial dysfunction assessed by speckle-tracking in good-grade subarachnoid hemorrhage patients (WFNS 1-2): a prospective observational study.

de Courson Hugues, Chadefaux Grégoire, Loiseau Alexandre, Georges Delphine, Biais Matthieu

Наблюдательное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Cardiac complications due to non-traumatic subarachnoid hemorrhage (SAH) are usually described using classical echocardiographic evaluation. Strain imaging appears to have better sensitivity than standard echocardiographic markers for the diagnosis of left ventricular dysfunction. The aim of this study was to determine the prevalence of cardiac dysfunction defined as a Global Longitudinal Strain (GLS) ≥  - 20% in patients with good-grade SAH (WFNS 1 or 2).

METHODS

Seventy-six patients with good-grade SAH were prospectively enrolled and analyzed at admission for neurocritical care. Transthoracic echocardiography was performed on days 1, 3, and 7 after hemorrhage. Routine measurements, including left ventricular ejection fraction (LVEF), were performed, and off-line analysis was performed by a blinded examiner, to determine 2-, 3-, and 4-cavity longitudinal strain and left ventricular GLS. GLS was considered altered if it was ≥  - 20%, we also interested the value of ≥  - 17%. LVEF was considered altered if it was < 50%.

RESULTS

On day 1, 60.6% of patients had GLS ≥  - 20% and 21.2% of patient had GLS ≥  - 17%. In comparison, alteration of LVEF was present in only 1.7% of patients. The concordance rate between LVEF < 50% and GLS ≥  - 20% and LVEF ≥ 50% and GLS <  - 20% was 46%.

CONCLUSION

Strain imaging showed a higher prevalence (60.6%) of left ventricular dysfunction during the acute phase of good-grade SAH (WFNS 1 or 2) than previously described.

Для цитирования: de Courson Hugues, Chadefaux Grégoire, Loiseau Alexandre, Georges Delphine, Biais Matthieu. Myocardial dysfunction assessed by speckle-tracking in good-grade subarachnoid hemorrhage patients (WFNS 1-2): a prospective observational study.. Critical care (London, England). 2023. DOI: 10.1186/s13054-023-04738-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.