MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5056/jnm19045

Медицинская библиотека · Journal of neurogastroenterology and motility · 2019

Five-fold Gastrointestinal Electrical Stimulation With Electromyography-based Activity Analysis: Towards Multilocular Theranostic Intestinal Implants.

Schiemer Jonas F, Heimann Axel, Somerlik-Fuchs Karin H, Ruff Roman, Hoffmann Klaus-Peter, Baumgart Jan, Berres Manfred, Lang Hauke, Kneist Werner

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND/AIMS: Motility disorders are common and may affect the entire gastrointestinal (GI) tract but current treatment is limited. Multilocular sensing of GI electrical activity and variable electrical stimulation (ES) is a promising option. The aim of our study is to investigate the effects of adjustable ES on poststimulatory spike activities in 5 GI segments.

METHODS

Six acute porcine experiments were performed with direct ES by 4 ES parameter sets (30 seconds, 25 mA, 500 microseconds or 1000 microseconds, 30 Hz or 130 Hz) applied through subserosal electrodes in the stomach, duodenum, ileum, jejunum, and colon. Multi-channel electromyography of baseline and post-stimulatory GI electrical activity were recorded for 3 minutes with hook needle and hook-wire electrodes. Spike activities were algorithmically calculated, visualized in a heat map, and tested for significance by Poisson analysis.

RESULTS

Post-stimulatory spike activities were markedly increased in the stomach (7 of 24 test results), duodenum (8 of 24), jejunum (23 of 24), ileum (18 of 24), and colon (5 of 24). ES parameter analysis revealed that 80.0% of the GI parts (all but duodenum) required a pulse width of 1000 microseconds, and 60.0% (all but jejunum and colon) required 130 Hz frequency for maximum spike activity. Five reaction patterns were distinguished, with 30.0% earlier responses (type I), 42.5% later or mixed type responses (type II, III, and X), and 27.5% non-significant responses (type 0).

CONCLUSIONS

Multilocular ES with variable ES parameters is feasible and may significantly modulate GI electrical activity. Automated electromyography analysis revealed complex reaction patterns in the 5 examined GI segments.

Для цитирования: Schiemer Jonas F, Heimann Axel, Somerlik-Fuchs Karin H, Ruff Roman, Hoffmann Klaus-Peter, Baumgart Jan, Berres Manfred, Lang Hauke, Kneist Werner. Five-fold Gastrointestinal Electrical Stimulation With Electromyography-based Activity Analysis: Towards Multilocular Theranostic Intestinal Implants.. Journal of neurogastroenterology and motility. 2019. DOI: 10.5056/jnm19045.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.