DOI 10.1016/j.brachy.2015.10.005
Rectal contrast increases rectal dose during vaginal cuff brachytherapy.
Аннотация
PURPOSE: To evaluate the impact of rectal dose on rectal contrast use during vaginal cuff brachytherapy (VCB).
METHODS AND MATERIALS: A retrospective review of gynecology patients who received some brachytherapy fractions with and without rectal contrast was carried out. Rectal contrast was instilled at the clinician's discretion to increase rectal visibility. Thirty-six pairs of CT scans in preparation for brachytherapy were analyzed. Pairs of CTs were segmented and planned using the same parameters. The rectum was always defined from 1 cm above the cylinder tip up to 1.5 cm below the last activated dwell source position. An individual plan was computed at every VCB fraction. A set of values (Dmax, D(0.1cc), D(1cc), and D(2cc)) derived from dose-volume histograms were extracted and compared according to the rectal status.
RESULTS
Rectal volume was 26.7% larger in the fractions with rectal contrast. Such an increase in volume represented a significant increase from 7.7% to 10.4% in all parameters analyzed except Dmax dose-volume histogram.
CONCLUSIONS
Avoiding rectal contrast is a simple way of decreasing the rectal dose parameters of VCB, which would mean a better therapeutic ratio. Results also suggest that action directed at maintaining the rectum empty might have the same effect.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.