MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1464-410x.1994.tb07607.x

Медицинская библиотека · British journal of urology · 1994

Correction of recurrent stress urinary incontinence by needle urethropexy with a vaginal wall sling.

Pidutti R W, George S W, Morales A

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To review the results of a modification of the transvaginal needle urethropexy as a treatment for patients developing recurrence after surgical correction of stress urinary incontinence (SUI).

SUBJECTS AND

METHODS

Twelve women who had undergone previous surgery for SUI and had developed recurrence of the symptoms were treated by a needle urethropexy technique which employed an island of in situ vaginal skin as a sling to support the bladder neck and urethra.

RESULTS

After a mean follow-up of 17.3 months, eight of the patients obtained excellent results, three experienced improvement and one was a failure.

CONCLUSIONS

The vaginal wall sling needle urethropexy was a simple technique to perform and carries a low morbidity. The results are similar to those of the more elaborate traditional sling procedures reported in the literature.

Для цитирования: Pidutti R W, George S W, Morales A. Correction of recurrent stress urinary incontinence by needle urethropexy with a vaginal wall sling.. British journal of urology. 1994. DOI: 10.1111/j.1464-410x.1994.tb07607.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.