MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiology.201.3.8939236

Медицинская библиотека · Radiology · 1996

Effect of the rate of gadopentetate dimeglumine administration on abdominal vascular and soft-tissue MR imaging enhancement patterns.

Strouse P J, Prince M R, Chenevert T L

СтатьяПеревод в очереди

Аннотация

PURPOSE: To delineate dynamic gadopentetate dimeglumine enhancement profiles within the abdomen as a guide to improve gadolinium-enhanced magnetic resonance (MR) angiography.

MATERIALS AND

METHODS

Fifteen patients (eight women, seven men; aged 19-80 years) underwent fast three-dimensional spoiled gradient-recalled-echo imaging with the keyhole technique during the administration of 0.1 mmol/kg gadopentetate dimeglumine by means of bolus (10-second) injection (n = 5), 60 second injection (n = 5), or slow (120-230-second) pump injection (n = 5). Injection was initiated 10 seconds after imaging began. Regions of interest were constructed within the aorta, inferior vena cava, liver, spleen, renal cortex, muscle, and fat. Inclusion of phantoms of gadopentetate dimeglumine in tubes allowed estimation of intravascular gadolinium concentration.

RESULTS

Maximal arterial enhancement occurred with bolus administration; maximal parenchymal organ enhancement, with 60-second injection. Slow pump injection resulted in a longer time to preferential arterial to venous enhancement (120 seconds +/- 14 [+/-standard deviation]) than did bolus (48 seconds +/- 64) or 60-second (88 seconds +/- 39) injections. The peak arterial to venous enhancement ratio was 6.3 +/- 3.3 for the bolus injection, 4.7 +/- 1.6 for the 60-second injection, and 3.3 +/- 1.3 for the slow pump injection.

CONCLUSION

The dynamics and magnitude of abdominal vascular and soft-tissue enhancement are affected by the rate of gadopentetate dimeglumine administration.

Для цитирования: Strouse P J, Prince M R, Chenevert T L. Effect of the rate of gadopentetate dimeglumine administration on abdominal vascular and soft-tissue MR imaging enhancement patterns.. Radiology. 1996. DOI: 10.1148/radiology.201.3.8939236.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.