Hoeben Bianca A W, Seravalli Enrica, Wood Amber M L, Bosman Mirjam, Matysiak Witold P, Maduro John H, van Lier Astrid L H M W, Maspero Matteo, Bol Gijsbert H, Janssens Geert O

Аннотация

PURPOSE: Optic nerves are part of the craniospinal irradiation (CSI) target volume. Modern radiotherapy techniques achieve highly conformal target doses while avoiding organs-at-risk such as the lens. The magnitude of eye movement and its influence on CSI target- and avoidance volumes are unclear. We aimed to evaluate the movement-range of lenses and optic nerves and its influence on dose distribution of several planning techniques.

METHODS: Ten volunteers underwent MRI scans in various gaze directions (neutral, left, right, cranial, caudal). Lenses, orbital optic nerves, optic discs and CSI target volumes were delineated. 36-Gy cranial irradiation plans were constructed on synthetic CT images in neutral gaze, with Volumetric Modulated Arc Therapy, pencil-beam scanning proton therapy, and 3D-conventional photons. Movement-amplitudes of lenses and optic discs were analyzed, and influence of gaze direction on lens and orbital optic nerve dose distribution.

RESULTS: Mean eye structures' shift from neutral position was greatest in caudal gaze; -5.8±1.2 mm (±SD) for lenses and 7.0±2.0 mm for optic discs. In 3D-conventional plans, caudal gaze decreased Mean Lens Dose (MLD). In VMAT and proton plans, eye movements mainly increased MLD and diminished D98 orbital optic nerve (D98OON) coverage; mean MLD increased up to 5.5 Gy [total ΔMLD range -8.1 to 10.0 Gy], and mean D98OON decreased up to 3.3 Gy [total ΔD98OON range -13.6 to 1.2 Gy]. VMAT plans optimized for optic disc Internal Target Volume and lens Planning organ-at-Risk Volume resulted in higher MLD over gaze directions. D98OON became ≥95% of prescribed dose over 95/100 evaluated gaze directions, while all-gaze bilateral D98OON significantly changed in 1 of 10 volunteers.

CONCLUSION: With modern CSI techniques, eye movements result in higher lens doses and a mean detriment for orbital optic nerve dose coverage of <10% of prescribed dose.