MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/00016489.2020.1764618

Медицинская библиотека · Acta oto-laryngologica · 2020

Microdrill stapedotomy for otosclerosis with small and large preoperative air-bone gap: a retrospective comparison of results.

Canale Andrea, Albera Andrea, Macocco Francesco, Caranzano Federico, Albera Roberto

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

Background

In otosclerosis mixed hearing loss is the most frequent symptom and arises when the focus involves the stapes footplate. Surgeons usually prefer to wait a minimum air-bone gap of 25 - 35 dB before surgery.

Objectives

To evaluate the outcome of microdrill stapedotomy for otosclerosis in patients with a preoperative air-bone gap (ABG) <25 dB versus patients with a preoperative gap ≥ 25 dB.Material and methods: For this retrospective study, the outcomes and complications after microdrill stapedotomy were compared between adult patients with a preoperative small ABG (n = 127, ABG <25 dB) and those with a large ABG (n = 254, ABG ≥25 dB).

Results

The postoperative ABG was significantly smaller than the preoperative ABG (p < .05) in both groups; there were no differences in complications rates (severe sensorineural hearing loss, footplate fracture or early postoperative vertigo) between the two groups.

Conclusions

Our findings show that microdrill stapedotomy is safe and can be performed even in patients with a preoperative small ABG without increasing the risk of sensorineural hearing loss due to inner ear damage.

Для цитирования: Canale Andrea, Albera Andrea, Macocco Francesco, Caranzano Federico, Albera Roberto. Microdrill stapedotomy for otosclerosis with small and large preoperative air-bone gap: a retrospective comparison of results.. Acta oto-laryngologica. 2020. DOI: 10.1080/00016489.2020.1764618.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.