Is Nebulized Lidocaine Adequate Topical Anesthesia for Diagnostic Transnasal Tracheoscopy?
Аннотация
OBJECTIVES
To evaluate if nebulized 4% lidocaine alone provides adequate laryngopharyngeal anesthesia for office-based diagnostic transnasal tracheoscopy (TNT).
METHODS
A retrospective chart review (January 2011 to June 2014) and a prospective case series (July 2014 to December 2014) of patients who underwent diagnostic TNT were performed at a university voice and swallowing center. TNT cases were categorized by method of topical laryngopharyngeal anesthesia: nebulized 4% lidocaine and 4% lidocaine drip (phase I) and nebulized 4% lidocaine only (phase II).
RESULTS
TNT was performed a total of 59 times on 38 patients. Eleven (69%) of 16 phase I TNT procedures involved significant patient discomfort and severe cough following the lidocaine drip. Forty-two (98%) of 43 phase II TNT procedures were completed comfortably; 1 case required additional anesthesia by lidocaine drip. Retrospectively, 100% (n=8) of patients who underwent both phase I and phase II TNTs were noted to prefer anesthesia with nebulizer alone. In a prospective case series of 14 phase II TNT cases, 6 (86%) of 7 patients who previously underwent phase I TNT reported preference for anesthesia with nebulizer alone.
CONCLUSIONS
Nebulized lidocaine appears to provide sufficient laryngopharyngeal anesthesia for diagnostic TNT. It is preferred by patients over laryngeal drip.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.