MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/00222895.2024.2324903

Медицинская библиотека · Journal of motor behavior · 2024

Motion Analysis of the Mug Transportation Task Through Upper Limb Kinematics.

Freire Bruno, Silva Letícia Yolanda, Espindola Kalebe Anilton, da Rocha Jéssica Roberta de Oliveira, Michaelsen Stella Maris

СтатьяПеревод пока не подготовлен

Аннотация

The task of transporting objects is a fundamental part of daily living activities. Previous kinematic studies focusing on tasks such as pointing, reach-to-grasp, and drinking have not fully captured the motor behaviors involved in object transportation, including placing a cup on a table or storing items in specific places. Hence, this study aimed to analyze the motor behavior associated with transporting a mug using upper limb kinematic variables. Fifteen healthy adults were instructed to transport an open-handle mug across a table. The kinematic metrics evaluated included object end-error for accuracy, frontal and lateral end-range for precision, movement time, peak velocity, time to peak velocity for control strategy, object path ratio for efficiency, and interjoint coordination. The stability of motor behavior was assessed through a test-retest analysis. The mug transporting task achieved accuracy with a radius <10 mm around the target, a peak velocity of ∼0.4 m/s, a control strategy where acceleration time constituted about 30% of the movement time, and a slightly curved trajectory. The test-retest analysis confirmed stable motor behavior across all kinematic metrics (ICCs > 0.75). Thus, the mug transporting task exhibited unique and stable kinematic characteristics, distinguishing it from non-transport activities and effectively mirroring transporting activities of daily living.

Для цитирования: Freire Bruno, Silva Letícia Yolanda, Espindola Kalebe Anilton, da Rocha Jéssica Roberta de Oliveira, Michaelsen Stella Maris. Motion Analysis of the Mug Transportation Task Through Upper Limb Kinematics.. Journal of motor behavior. 2024. DOI: 10.1080/00222895.2024.2324903.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.