MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vcp.12843

Медицинская библиотека · Veterinary clinical pathology · 2020

Multicenter flow cytometry proficiency testing of canine blood and lymph node samples.

Meichner Kristina, Stokol Tracy, Tarigo Jaime, Avery Anne, Burkhard Mary J, Comazzi Stefano, Fogle Jonathan, Stowe Devorah Marks, Rütgen Barbara, Seelig Davis, Wasserkrug-Naor Adi, Vernau William, Bienzle Dorothee

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Flow cytometry (FC) is used increasingly in veterinary medicine for further characterization of hematolymphoid cells. Guidelines for optimizing assay performance and interpretation of results are limited, and concordance of results across laboratories is unknown.

OBJECTIVES

This study aimed to determine inter-investigator agreement on the interpretation of FC results from split samples analyzed in different laboratories using various protocols, cytometers, and software; and on the interpretation of archived FC standard (FCS) data files contributed by the different investigators.

METHODS

This was a multicenter observational cross-sectional study. Anticoagulated blood or lymph node aspirate samples from nine client-owned dogs were aliquoted and shipped to participating laboratories. Samples were analyzed with individual laboratory-developed protocols. In addition, FCS files from a set of separate samples from 11 client-owned dogs were analyzed by participating investigators. A person not associated with the study tabulated the results and interpretations. Agreement of interpretations was assessed with Fleiss' kappa statistic.

RESULTS

Prolonged transit times affected sample quality for some laboratories. Overall agreement among investigators regarding the FC sample interpretation was strong (κ = 0.86 ± 0.19, P < .001), and for specific categories, ranged from moderate to perfect. Agreement of the lymphoproliferation or other leukocyte sample category from the analysis of the FCS files was weak (κ = 0.58 ± 0.05, P < .001).

CONCLUSIONS

Lymphoproliferations were readily identified by FC, but identification of the categories of hematolymphoid neoplasia in fresh samples or archived files was variable. There is a need for a more standardized approach to maximize the enormous potential of FC in veterinary medicine.

Для цитирования: Meichner Kristina, Stokol Tracy, Tarigo Jaime, Avery Anne, Burkhard Mary J, Comazzi Stefano, Fogle Jonathan, Stowe Devorah Marks, Rütgen Barbara, Seelig Davis, Wasserkrug-Naor Adi, Vernau William, Bienzle Dorothee. Multicenter flow cytometry proficiency testing of canine blood and lymph node samples.. Veterinary clinical pathology. 2020. DOI: 10.1111/vcp.12843.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.