Auris, nasus, larynx · 2019
Detectability of minute temporal bone structures with ultra-high resolution CT.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Hiraumi Harukazu, Obara Makiko, Yoshioka Kunihiro, Ehara Shigeru, Sato Hiroaki
Аннотация
OBJECTIVE: Computed tomography (CT) is the imaging tool of choice in the diagnosis of temporal bone lesions. With the recent progress in imaging technology, CT with higher spatial resolution (Ultra-high resolution CT) has become available in the clinical setting. The purpose of this study is to evaluate the visibility of small temporal bone structures using ultra-high resolution CT.
MATERIAL AND METHODS: The visibility of 27 minute temporal bone structures on ultra-high resolution CT images was evaluated. Non-helical axial scans were performed in 18 normal hearing ears without previous otologic diseases. Visibility was scored by an experienced radiologist and otologist.
RESULTS: Minute temporal bone structures including the ossicular chain, the crus of the stapes, the greater superficial petrosal nerve, and the anterior malleolar ligament were clearly visualized on ultra-high resolution CT. The stapedius muscle tendon and the chorda tympani exiting the posterior canaliculus and coursing medial to the malleus could be visualized.
CONCLUSION: Ultra-high resolution CT provides good visualization of small temporal bone structures in normal subjects.
MATERIAL AND METHODS: The visibility of 27 minute temporal bone structures on ultra-high resolution CT images was evaluated. Non-helical axial scans were performed in 18 normal hearing ears without previous otologic diseases. Visibility was scored by an experienced radiologist and otologist.
RESULTS: Minute temporal bone structures including the ossicular chain, the crus of the stapes, the greater superficial petrosal nerve, and the anterior malleolar ligament were clearly visualized on ultra-high resolution CT. The stapedius muscle tendon and the chorda tympani exiting the posterior canaliculus and coursing medial to the malleus could be visualized.
CONCLUSION: Ultra-high resolution CT provides good visualization of small temporal bone structures in normal subjects.