Medical dosimetry : official journal of the American Association of Medical Dosimetrists · 2023
Feasibility-guided automated planning for stereotactic treatments of prostate cancer.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Romano Carmela, Viola Pietro, Craus Maurizio, Macchia Gabriella, Ferro Milena, Bonome Paolo, Pierro Antonio, Buwenge Milly, Arcelli Alessandra, Morganti Alessio Giuseppe, Deodato Francesco, Cilla Savino
Аннотация
Significant improvements in plan quality using automated planning have been previously demonstrated. The aim of this study was to develop an optimal automated class solution for stereotactic radiotherapy (SBRT) planning of prostate cancer using the new Feasibility module implemented in the pinnacle evolution. Twelve patients were retrospectively enrolled in this planning study. Five plans were designed for each patient. Four plans were automatically generated using the 4 proposed templates for SBRT optimization implemented in the new pinnacle evolution treatment planning systems, differing for different settings of dose-fallout (low, medium, high and veryhigh). Based on the obtained results, the fifth plan (feas) was generated customizing the template with the optimal criteria obtained from the previous step and integrating in the template the "a-priori" knowledge of OARs sparing based on the Feasibility module, able to estimate the best possible dose-volume histograms of OARs before starting optimization. Prescribed dose was 35 Gy to the prostate in 5 fractions. All plans were generated with a full volumetric-modulated arc therapy arc and 6MV flattening filter-free beams, and optimized to ensure the same target coverage (95% of the prescription dose to 98% of the target). Plans were assessed according to dosimetric parameters and planning and delivery efficiency. Differences among the plans were evaluated using a Kruskal-Wallis 1-way analysis of variance. The requests for more aggressive objectives for dose falloff parameters (from low to veryhigh) translated in a statistically significant improvement of dose conformity, but at the expense of a dose homogeneity. The best automated plans in terms of best trade-off between target coverage and OARs sparing among the 4 plans automatically generated by the SBRT module were the high plans. The veryhigh plans reported a significant increase of high-doses to prostate, rectum, and bladder that was considered dosimetrically and clinically unacceptable. The feas plans were optimized on the basis on high plans, reporting significant reduction of rectum irradiation; Dmean, and V18 decreased by 19% to 23% (p = 0.031) and 4% to 7% (p = 0.059), respectively. No statistically significant differences were found in femoral heads and penile bulb irradiation for all dosimetric metrics. feas plans showed a significant increase of MU/Gy (mean: 368; p = 0.004), reflecting an increased level of fluence modulation. Thanks to the new efficient optimization engines implemented in pinnacle evolution (L-BFGS and layered graph), mean planning time was decreased to less than 10 minutes for all plans and all techniques. The integration of dose-volume histograms a-priori knowledge provided by the feasibility module in the automated planning process for SBRT planning has shown to significantly improve plan quality compared to generic protocol values as inputs.