A multi-center evaluation of a disposable catheter to aid in correct positioning of the endotracheal tube after intubation in critically ill patients.

Cohen Avi, Tan Laren, Fargo Ramiz, Anholm James D, Gasho Chris, Yaqub Kashif, Chopra Sahil, Hansen Jennifer, Huang Cynthia, Moretta Dafne, Washburn Destry, Bryant Nguyen H

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To demonstrate that use of a minimally invasive catheter reduces endotracheal tube (ETT) malposition rate after intubation.

MATERIALS AND

METHODS

This study is a multi-center, prospective observational cohort of intubated patients in the medical intensive care unit. The catheter was inserted into the ETT immediately after intubation. The ETT was adjusted accordingly based on qualitative color markers on the catheter. A confirmatory chest radiograph was obtained to determine the ETT position. Malposition of the ETT was defined by the distal ETT not being within 2-5 cm above the carina.

RESULTS

Sixty-nine patients were enrolled, age 56.2 ± 19.5 years, body mass index 31.0 ± 13.8 kg/m2. The catheter prompted repositioning of the ETT in 39 (56.5%) patients. Using the catheter, the rate of malposition decreased to 7.2%, with the distal ETT position at 3.7 ± 1.2 cm above the carina. Without the catheter, the ETT malposition rate would have been 39.1%. The time for catheter use and chest radiograph completion at our institutions was 1.7 ± 1.5 and 44.4 ± 36.4 min, respectively.

CONCLUSIONS

With use of an ETT positioning catheter after intubation, the ETT malposition rate was reduced by 82%. This catheter-based system was safe, and its use may perhaps decrease the need for the post-intubation chest radiograph.

Для цитирования: Cohen Avi, Tan Laren, Fargo Ramiz, Anholm James D, Gasho Chris, Yaqub Kashif, Chopra Sahil, Hansen Jennifer, Huang Cynthia, Moretta Dafne, Washburn Destry, Bryant Nguyen H. A multi-center evaluation of a disposable catheter to aid in correct positioning of the endotracheal tube after intubation in critically ill patients.. Journal of critical care. 2018. DOI: 10.1016/j.jcrc.2018.09.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.