Intraobserver and interobserver reliability of standardized capillary refill time in dogs is high following observer training.

Claret Aina, Gelendi Stefania, Kuo Kendon, McMichael Maureen, Gerken Katherine, Liao Pen-Ting

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To assess intraobserver and interobserver reliability of capillary refill time (CRT) measurement in dogs using a standardized technique after training.

ANIMALS: 20 dogs presented to the emergency room.

METHODS

Dogs presented to the emergency room were prospectively recruited. Using a timing device and standardized technique, CRT was measured at the oral mucosa of the inner lip. Measurements were performed by 2 emergency and critical care residents (observer 1 [Ob1] and observer 2 [Ob2]) and repeated 3 times by each observer for each dog. CRT values and signalment were recorded. Intraobserver and interobserver reliability were analyzed by calculation of the coefficient of variation (CV%), intraclass correlation coefficient (ICC), and minimal detectable difference. Reliability was considered high if CV% was lower than 10% and ICC was between 0.9 and 1.

RESULTS

Median CRT for Ob1 was 1.22 seconds and for Ob2 was 1.19 seconds. Intraobserver reliability was high, evidenced by a median CV% of 6.2% (range, 1.0% to 18.6%) and 9.5% (range, 1.3% to 22.6%) and an ICC of 0.97 (95% CI, 0.94 to 0.99) and 0.95 (95% CI, 0.90 to 0.98) for Ob1 and Ob2, respectively. Between observers, the CV% was 4.4% (range, 0.8% to 17.5%) and the ICC was 0.98 (95% CI, 0.94 to 0.99), indicating high interobserver reliability. The minimal detectable differences for intraobserver and interobserver were 0.30 and 0.34 seconds, respectively.

CLINICAL RELEVANCE: The reported high reliability of CRT despite its subjective nature enhances its usefulness in daily practice. However, further research on the validity of CRT is warranted.

Для цитирования: Claret Aina, Gelendi Stefania, Kuo Kendon, McMichael Maureen, Gerken Katherine, Liao Pen-Ting. Intraobserver and interobserver reliability of standardized capillary refill time in dogs is high following observer training.. Journal of the American Veterinary Medical Association. 2023. DOI: 10.2460/javma.23.07.0417.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.