International urology and nephrology · 2015
Penile enhancement with rectus muscle fascia and testicular tunica vaginalis grafts: an experimental animal study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Bagbanci Sahin, Dadali Mumtaz, Emir Levent, Aydogmus Yasin, Ozer Elif
Аннотация
PURPOSE: To enhance rat penises experimentally with rectus muscle fascia (RMF) and testicular tunica vaginalis grafts (TVG).
METHODS: Twelve Wistar albino rats were distributed into two equal Groups, A and B. There were six rats in each group. RMF and TVG were used to enhance rat penises in Groups A and B, respectively. Circumferences of the penises were measured preoperatively and at three different times after the operation. Two, two and eight rats were killed 10 days, 1 month and 2 months after the operation, respectively, for histopathological examinations.
RESULTS: When we compared the measurements of preoperative and immediately postoperative circumferences, the mean increase was 23.4 ± 2.9 % in Group A and 19.9 ± 1.7 % in Group B. According to paired t test, the difference was significant (p < 0001), but the comparison between preoperative and postoperative first-month measurements was not found to be significant (p > 0.05). Histological examinations revealed an intensive inflammatory process at 10 days after the operation. Grafts were found to be totally absorbed in the first- and second-month examinations.
CONCLUSION: In our study, implanted TVG and RMF could not survive because of insufficient vascularization and failure to maintain satisfactory surgical success. More studies are needed to increase the effectiveness of surgical techniques.
METHODS: Twelve Wistar albino rats were distributed into two equal Groups, A and B. There were six rats in each group. RMF and TVG were used to enhance rat penises in Groups A and B, respectively. Circumferences of the penises were measured preoperatively and at three different times after the operation. Two, two and eight rats were killed 10 days, 1 month and 2 months after the operation, respectively, for histopathological examinations.
RESULTS: When we compared the measurements of preoperative and immediately postoperative circumferences, the mean increase was 23.4 ± 2.9 % in Group A and 19.9 ± 1.7 % in Group B. According to paired t test, the difference was significant (p < 0001), but the comparison between preoperative and postoperative first-month measurements was not found to be significant (p > 0.05). Histological examinations revealed an intensive inflammatory process at 10 days after the operation. Grafts were found to be totally absorbed in the first- and second-month examinations.
CONCLUSION: In our study, implanted TVG and RMF could not survive because of insufficient vascularization and failure to maintain satisfactory surgical success. More studies are needed to increase the effectiveness of surgical techniques.