m+Medelevator.RU
← Поиск публикаций
Journal of minimally invasive gynecology · 2015

Hysteroscopic Myomectomy of FIGO Type 2 Leiomyomas Under Local Anesthesia: Bipolar Radiofrequency Needle-Based Release Followed By Electromechanical Morcellation.

СтатьяVideo-Audio MediaНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Munro Malcolm G

Аннотация

OBJECTIVE: To demonstrate a technique designed to expand the capabilities of hysteroscopic intrauterine morcellators to deep type 1 and type 2 lesions. The technique comprises "release" of the tumor using a bipolar radiofrequency needle, followed by dissection and extraction with an electromechanical morcellator, all under local anesthesia.

DESIGN: Description of technique using images and video (Canadian Task Force classification Class III).

SETTING: Office uterine procedure and imaging center; academic medical center.

INTERVENTION: Following the administration of local anesthesia and access to the endometrial cavity with a 5.5-mm-o.d. hysteroscopic sheath with a 5 Fr operative channel, a 5 Fr bipolar needle electrode system is used to circumscribe the leiomyoma and enter the pseudocapsule, thereby "releasing" the lesion. Blunt dissection is performed as appropriate and then the system is switched to a hysteroscopic morcellating system (MyoSure; Hologic, Bedford, MA), which is then used to further dissect and remove the target lesion with electromechanical morcellation.

CONCLUSION: The development of intrauterine morcellators has facilitated the performance of hysteroscopic myomectomy, especially under local anesthesia, but the side aperture-based design of the systems limits their use in International Federation of Gynecology and Obstetrics (FIGO) type 1 and 2 tumors, particularly those located at the uterine fundus. This technique, based in part on a previously published technique of leiomyoma release, improves access of the electromechanical morcellator to leiomyomas that previously were inaccessible, and minimizes myometrial trauma by dissecting the tumor via the relatively avascular pseudocapsule.

Предметные рубрики MeSH