DOI 10.1016/j.xops.2025.100723
Population-Based Normative Reference for Retinal Microvascular Atlas.
Аннотация
OBJECTIVE
To establish the normative range of a comprehensive set of retinal vascular measurements to better understand their value as biomarkers for assessing ocular and systemic health.
DESIGN
Cross-sectional study.
PARTICIPANTS
The study included 10 151 healthy participants from the UK Biobank.
METHODS
Retina-based Microvascular Health Assessment System software was used to extract retinal vascular measurements, including caliber, complexity, density, branching angle, and tortuosity, differentiating between arteries and veins and between the macula and retinal periphery. In addition, we explored relationships between those measurements and health metrics, including age, systolic blood pressure (SBP), body mass index, glycated hemoglobin, and intraocular pressure.
MAIN OUTCOME MEASURES: We reported the population normative range for 114 retinal vascular measurements, further stratified by sex and age.
RESULTS
The mean values of central retinal artery equivalent and central retinal vein equivalent (CRVE) were 152 (standard deviation = 14.9) μm and 233 (21.5) μm, respectively. The mean value of fractal dimension (FD) was 1.77 (0.032), with arterial FD 1.53 (0.039) and venular FD 1.56 (0.025). Age and SBP showed the strongest associations with most retinal parameters among health metrics. Central retinal artery equivalent, CRVE, density, and complexity decreased with increasing age and SBP. Changes in arterial measurements with age and SBP were generally greater than those in venous measurements. Generalized additive models further revealed that observed associations were mainly linear.
CONCLUSIONS
By establishing population normative data for a comprehensive set of retinal vascular measurements, our study enables quantifiable approaches to better understand retinal vascular changes.
FINANCIAL DISCLOSURES: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.