MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ijg.0000000000001554

Медицинская библиотека · Journal of glaucoma · 2020

Efficacy of Combined Suprachoroidal Stent and Cataract Surgery in Patients With Glaucoma.

Law Simon K, Salazar Diana, Yu Fei, Giaconi JoAnn A, Chen Angela, Chopra Vikas, Francis Brian, Coleman Anne L, Lu Kenneth, Nouri-Mahdavi Kouros, Tan James, Caprioli Joseph

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of this study was to evaluate the efficacy of intraocular pressure (IOP) control after combined CyPass Micro-Stent implantation and cataract surgery (combined surgery).

METHODS

All cases of combined surgery performed from February 2017 to July 2018 at Stein and Doheny Eye Institutes were reviewed. The primary outcome was a qualified success with stratified IOP targets based on criteria: final IOP (A) ≤18 mm Hg and reduction of 20%, (B) ≤15 mm Hg and reduction of 25%, (C) ≤12 mm Hg and reduction of 30%. Secondary outcome measures included postoperative IOP and number of medications, complications, additional glaucoma surgery, and postoperative refractive error. Predictive factors for failure were investigated. IOP spike was defined as a postoperative IOP ≥30 or >10 mm Hg increase from preoperative IOP.

RESULTS

One hundred forty-one eyes (107 patients) were included. Mean (±SD) preoperative IOP was 15.4±3.4 mm Hg on an average of 2.2±1.1 medications. A statistically significant reduction in IOP and number of medications was seen at 12 months (13.8±4.2 mm Hg, 1.3±1.3 medications, P<0.001). Fifteen eyes (10.6%) had a postoperative IOP spike. Thirteen eyes (9.2%) experienced 17 complications (12.1%). Additional glaucoma surgery was performed in 3 eyes (2 patients). Cumulative success rates at 1 year based on criteria A, B, and C were 42%, 33%, and 28%, respectively. Lower preoperative IOP, greater preoperative medication number, the occurrence of postoperative IOP spike, and non-Caucasian ethnicity were associated with failure.

CONCLUSION

Combined CyPass Micro-Stent implantation and cataract surgery may reduce glaucoma medication burden with a success rate of 28% to 42% at 1 year.

Для цитирования: Law Simon K, Salazar Diana, Yu Fei, Giaconi JoAnn A, Chen Angela, Chopra Vikas, Francis Brian, Coleman Anne L, Lu Kenneth, Nouri-Mahdavi Kouros, Tan James, Caprioli Joseph. Efficacy of Combined Suprachoroidal Stent and Cataract Surgery in Patients With Glaucoma.. Journal of glaucoma. 2020. DOI: 10.1097/ijg.0000000000001554.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.