MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1113/jphysiol.2010.196204

Медицинская библиотека · The Journal of physiology · 2010

Tissue contribution to the mechanical features of diaphragmatic initial lymphatics.

Moriondo Andrea, Boschetti Federica, Bianchin Francesca, Lattanzio Simone, Marcozzi Cristiana, Negrini Daniela

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The role of the mechanical properties of the initial lymphatic wall and of the surrounding tissue in supporting lymph formation and/or progression was studied in six anaesthetized, neuromuscularly blocked and mechanically ventilated rats. After mid-sternal thoracotomy, submesothelial initial lymphatics were identified on the pleural diaphragmatic surface through stereomicroscopy. An 'in vivo' lymphatic segment was prepared by securing two surgical threads around the vessel at a distance of ∼2.5 mm leaving the vessel in place. Two glass micropipettes were inserted into the lumen, one for intraluminar injections of 4.6 nl saline boluses and one for hydraulic pressure (Plymph) recording. The compliance of the vessel wall (Clymph) was calculated as the slope of the plot describing the change in segment volume as a function of the post-injection Plymph changes. Two superficial lymphatic vessel populations with a significantly different Clymph (6.7 ± 1.6 and 1.5 ± 0.4 nl mmHg−1 (mean ± S.E.M.), P < 0.001) were identified. In seven additional rats, the average elastic modulus of diaphragmatic tissue strips was determined by uniaxial tension tests to be 1.7 ± 0.3 MPa. Clymph calculated for an initial lymphatic completely surrounded by isotropic tissue was 0.068 nl mmHg−1, i.e. two orders of magnitude lower than in submesothelial lymphatics. Modelling of stress distribution in the lymphatic wall suggests that compliant vessels may act as reservoirs accommodating large absorbed fluid volumes, while lymphatics with stiffer walls serve to propel fluid through the lumen of the lymphatic vessel by taking advantage of the more efficient mechanical transmission of tissue stresses to the lymphatic lumen.

Для цитирования: Moriondo Andrea, Boschetti Federica, Bianchin Francesca, Lattanzio Simone, Marcozzi Cristiana, Negrini Daniela. Tissue contribution to the mechanical features of diaphragmatic initial lymphatics.. The Journal of physiology. 2010. DOI: 10.1113/jphysiol.2010.196204.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.