MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/1361-6560/aae78c

Медицинская библиотека · Physics in medicine and biology · 2018

In vivo measurement of the effective atomic number of breast skin using spectral mammography.

Berggren Karl, Eriksson Mikael, Hall Per, Wallis Matthew G, Fredenberg Erik

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

X-ray characteristics of body tissues are of crucial importance for developing and optimizing x-ray imaging techniques, in particular for dosimetry and spectral imaging applications. For breast imaging, the most important tissues are fibro-glandular, adipose and skin tissue. Some work has and is being done to better characterize these tissue types, in particular fibro-glandular and adipose tissue. In the case of breast skin, several recent studies have been published on the average skin thickness, but with regards to x-ray attenuation, the only published data, to the knowledge of the authors, is the elemental composition analysis of Hammerstein et al (1979 Radiology 130 485-91). This work presents an overview of breast skin thickness studies and a measurement of the effective atomic number ([Formula: see text]) of breast skin using spectral mammography. [Formula: see text], which together with the density forms the attenuation, is used to validate the work by Hammerstein et al, and the dependence of clinical parameters on [Formula: see text] is explored. Measurements were conducted on the skin edge of spectral mammograms using clinical data from a screening population (n  =  709). The weighted average of breast skin thickness reported in studies between 1997 and 2013 was found to be [Formula: see text] mm. Mean [Formula: see text] was found to be 7.365 (95% CI: 7.364,7.366) for normal breast skin and 7.441 (95% CI: 7.440,7.442) for the nipple and areola. [Formula: see text] of normal breast skin is in agreement with Hammerstein et al, despite the different methods and larger sample size used. A small but significant increase in [Formula: see text] was found with age, but the increase is too small to be relevant for most applications. We conclude that normal breast skin is well described by a 1.56 mm skin layer and the elemental composition presented by Hammerstein et al (1979 Radiology 130 485-91) and recommend using these characteristics when modelling breast skin.

Для цитирования: Berggren Karl, Eriksson Mikael, Hall Per, Wallis Matthew G, Fredenberg Erik. In vivo measurement of the effective atomic number of breast skin using spectral mammography.. Physics in medicine and biology. 2018. DOI: 10.1088/1361-6560/aae78c.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.