MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/dc.23476

Медицинская библиотека · Diagnostic cytopathology · 2016

Immunocytochemical utility of claudin-4 versus those of Ber-EP4 and MOC-31 in effusion cytology.

Oda Tomohiro, Ogata Sho, Kawaguchi Saki, Minabe Shinya, Dokyu Misaki, Takahashi Hiromi, Kumazawa Fumihiko, Shimazaki Hideyuki, Takano Masashi, Hase Kazuo, Ozeki Yuichi, Kanoh Soichiro, Nakanishi Kuniaki

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Recently, claudin-4 (CL4) immunocytochemistry was reported to be useful for differential diagnosis in effusion cytology. We wondered whether CL4 might be useful for "single-shot" identification of metastatic carcinoma. The purpose of this study was to evaluate the usefulness of CL4 in effusion cytology.

METHODS

In total, 266 cases (169 metastatic carcinomas, eight malignant mesotheliomas, and 89 reactive mesothelial cells) were selected. Immunocytochemical examinations of cell-block sections were performed for CL4, Ber-EP4, and MOC-31. We used an arbitrary 4-tiered scale based on both staining intensity and positive-cell percentage among all target cells, and calculated a staining index score (sum of the above two scores).

RESULTS

In a ROC-curve analysis, higher area-under-curve values were found for CL4 than for Ber-EP4 or MOC-31 (0.982, 0.942, and 0.926, respectively).

CONCLUSIONS

Since CL4 exhibited similar or superior usefulness to Ber-EP4 and MOC-31, it could become the first choice for the above differential diagnosis in effusion cytology. Diagn. Cytopathol. 2016;44:499-504. © 2016 Wiley Periodicals, Inc.

Для цитирования: Oda Tomohiro, Ogata Sho, Kawaguchi Saki, Minabe Shinya, Dokyu Misaki, Takahashi Hiromi, Kumazawa Fumihiko, Shimazaki Hideyuki, Takano Masashi, Hase Kazuo, Ozeki Yuichi, Kanoh Soichiro, Nakanishi Kuniaki. Immunocytochemical utility of claudin-4 versus those of Ber-EP4 and MOC-31 in effusion cytology.. Diagnostic cytopathology. 2016. DOI: 10.1002/dc.23476.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.