m+Medelevator.RU
← Поиск публикаций
Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2023

Bone marrow sparing in prostate cancer patients treated with Post-operative pelvic nodal radiotherapy - A proton versus photon comparison.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

De Ornelas Mariluz, Iorio Giuseppe Carlo, Bossart Elizabeth, Ricardi Umberto, Seldon Crystal, Dal Pra Alan, Butkus Michael

Аннотация

PURPOSE: Extending salvage radiotherapy to treat the pelvic lymph nodes (PLNRT) improves oncologic outcomes in prostate cancer (PCa). However, a larger treatment volume increases the extent of bone marrow (BM) exposure, which is associated with hematologic toxicity (HT). Given the potential long-term impact of BM dose in PCa, clinical studies on BM sparing (BMS) are warranted. Herein, we dosimetrically compared photon and proton plans for BMS.

MATERIALS AND METHODS: Treatment plans of 20 post-operative PCa patients treated with volumetric-modulated arc photon therapy (VMAT) PLNRT were retrospectively identified. Contours were added for the whole pelvis BM (WPBM) and BM sub-volumes: lumbar-sacral (LSBM), iliac (ILBM), and lower pelvis (LPBM). Three additional plans were created: VMAT_BMS, intensity-modulated proton therapy (IMPT), and IMPT_BMS. Normal tissue complication probabilities (NTCP) for grade >3 hematologic toxicity (HT3+) were calculated for the WPBM volumes.

RESULTS: Compared to the original VMAT plan, mean doses to all BM sub-volumes were statistically significantly lower for VMAT_BMS, IMPT, and IMPT_BMS resulting in average NTCP percentages of 20.5 ± 5.9, 10.7 ± 4.2, 6.1 ± 2.0, and 2.5 ± 0.6, respectively. IMPT_BMS had significantly lower low dose metrics (V300cGy-V2000cGy) for WPBM and sub-volumes except for LPBM V2000cGy compared to VMAT_BMS and ILBM V20Gy compared to IMPT. In most cases, V4000cGy and V5000cGy within ILBM and LSBM were significantly higher for IMPT plans compared to VMAT plans.

CONCLUSIONS: BMS plans are achievable with VMAT and IMPT without compromising target coverage or OARs constraints. IMPT plans were overall better at reducing mean and NTCP for HT3+ as well as low dose volumes to BM. However, IMPT had larger high dose volumes within LSBM and ILBM. Further studies are warranted to evaluate the clinical implications of these findings.