[Restructuring Torso CT Protocol for Radiation Dose Management].

Yamaguchi Yuki, Fukunaga Masaaki, Mitsui Hideki, Nagaki Akio, Ito Osamu, Yamamoto Hiroyuki, Kawakami Yuji, Watanabe Daiki

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: There are problems with dose management in X-ray computed tomography (CT) because the protocol used for any examination is not always in the same scan range. The purpose of this study was to investigate the usefulness of setting the CT protocol based on the scan range.

METHODS

We evaluated the examination data of patients who underwent plain CT based on a scan range of chest to pelvis and abdomen to pelvis. The previous protocol [Chest-Abdomen Routine] was changed to the current protocols [Chest_Abdomen] and [Chest_Pelvis], and the previous protocol of [Abdomen Routine] was changed to the current protocols [Abdomen] and [Abdomen_Pelvis]. Examination data of height, scan length, volume CT dose index (CTDIvol), and dose length product (DLP) were obtained from digital imaging and communications in medicine, and radiation dose structured report using Radimetrics. The relationship between patient height and scan range, and CTDIvol and DLP was indicated in a scatter plot. Standard deviation (SD) of scan length and DLP were compared between current and previous protocols. Outliers were defined as the data exceeding average ±2SD.

RESULTS

The SD of scan length decreased by 77.1% on abdomen to pelvis, and the SD of DLP decreased by 65.2% on abdomen to pelvis. The causes of the outliers were CT scan range, scan parameter, arm position, metal implants, and body thickness of patients.

CONCLUSION

Setting CT protocols based on the scan range reduced SD of scan length and DLP. It was helpful for reducing the number of scan range outliers and analyzing the cause of outliers.

Для цитирования: Yamaguchi Yuki, Fukunaga Masaaki, Mitsui Hideki, Nagaki Akio, Ito Osamu, Yamamoto Hiroyuki, Kawakami Yuji, Watanabe Daiki. [Restructuring Torso CT Protocol for Radiation Dose Management].. Nihon Hoshasen Gijutsu Gakkai zasshi. 2022. DOI: 10.6009/jjrt.2022-1131.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.