m+Medelevator.RU
← Поиск публикаций
International journal of molecular medicine · 2009

Sensitivity and reproducibility of conventional qualitative and quantitative PCR assays for detection of the t(14;18)(q32;q21) chromosomal translocation in biopsy material from patients with follicular lymphoma.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kokovic Ira, Novakovic Barbara Jezersek, Grazio Snjezana Frkovic, Novakovic Srdjan

Аннотация

Follicular lymphoma (FL) is characterized by the t(14;18)(q32;q21) chromosomal translocation which can be detected by polymerase chain reaction (PCR) in approximately 70% of cases. The aim of our retrospective study was to evaluate the sensitivity and the reproducibility of both conventional qualitative and quantitative PCR assays for detection of the t(14;18)(q32;q21) chromosomal translocation in biopsy material. Fifty-seven formalin-fixed, paraffin-embedded tumor lymph node (LN) specimens from 50 patients with FL were included in the study. Qualitative PCR was performed with primer sets specific for the MBR, far3'-MBR and the mcr regions, respectively. Quantitative PCR was performed using the LightCycler instrument and the LightCycler - t(14;18) Quantification Kit (MBR). The overall detection rate of the t(14;18) in our study (52.6%) was in accordance with the literature. Of the t(14;18)-positive cases, 49.1% had breakpoints within the MBR and only 3.5% had breakpoints within the mcr. The most sensitive method was LightCycler-based PCR with a detection rate of 47.4%, followed by MBR1,2 assay (43.9%). We observed good agreement between qualitative MBR1,2 and quantitative LightCycler-based assay with a slightly higher detection rate of the quantitative method. The sensitivities of both methods were in accordance with results from other studies. Since LightCycler-based assay detects only breakpoints within the MBR, qualitative PCR should be employed in routine diagnostic settings for detection of breakpoints within the mcr and far3'-MBR regions.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты