m+Medelevator.RU
← Поиск публикаций
Radiology · 2010

Recurrent ovarian cancer: use of contrast-enhanced CT and PET/CT to accurately localize tumor recurrence and to predict patients' survival.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sala Evis, Kataoka Masako, Pandit-Taskar Neeta, Ishill Nicole, Mironov Svetlana, Moskowitz Chaya S, Mironov Oleg, Collins Michelle A, Chi Dennis S, Larson Steven, Hricak Hedvig

Аннотация

PURPOSE: To compare accuracy and interobserver variability in the detection and localization of recurrent ovarian cancer with contrast material-enhanced (CE) computed tomography (CT) and positron emission tomography (PET)/CT and determine whether imaging findings can be used to predict survival.

MATERIALS AND METHODS: Waiving informed consent, the institutional review board approved this HIPAA-compliant, retrospective study of 35 women (median age, 54.4 years) with histopathologically proven recurrent ovarian carcinoma who underwent CE CT and PET/CT before exploratory surgery. All CE CT and PET/CT scans were independently analyzed. Tumor presence, number of lesions, and the size and maximum standardized uptake value (SUV(max)) of the largest lesion were recorded for patient and region. Surgical histopathologic findings constituted the reference standard. Areas under the receiver operating characteristic curves (AUCs), κ statistics, and hazard ratios were calculated.

RESULTS: Readers' AUCs in detection of recurrence for region were 0.85 (95% confidence interval [CI]: 0.81, 0.90) and 0.78 (95% CI: 0.72, 0.83) for CE CT and 0.84 (95% CI: 0.79, 0.89) and 0.74 (95% CI: 0.67, 0.81) for PET/CT (P = .76); 12 patients died. At PET/CT, size, number, and SUV(max) of peritoneal deposits were significantly associated with poor survival for readers 1 and 2 (P ≤ .01and ≤ .05, respectively), as were long- and short-axis diameters, number, and SUV(max) of distant lymph nodes for reader 1 (P ≤ .001). With CE CT, size (reader 1) and number (readers 1 and 3) of peritoneal deposits were significantly associated with poor survival (P ≤ .01), as were long- and short-axis diameters and number of distant lymph nodes for reader 1 (P ≤ .01). Interobserver agreement ranged from fair (patient, κ = 0.30) to moderate (region, κ = 0.55) for CE CT and fair (patient, κ = 0.24) to substantial (region, κ = 0.63) for PET/CT.

CONCLUSION: Preliminary data suggest that CE CT and PET/CT may have similar accuracy in detection of recurrent ovarian cancer. Tumor size, number, and SUV(max) may have potential as prognostic biomarkers for patients with recurrent ovarian cancer.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты