MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00404-010-1442-0

Медицинская библиотека · Archives of gynecology and obstetrics · 2010

Region-based diagnostic performance of multidetector CT for detecting peritoneal seeding in ovarian cancer patients.

Choi Hyuck Jae, Lim Myong Cheol, Bae Jaeman, Cho Kyoung-Sik, Jung Dae Chul, Kang Sokbom, Yoo Chong Woo, Seo Sang-Soo, Park Sang-Yoon

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the accuracy of multi-detector CT (MDCT) compared with the surgical findings, such as peritoneal seeding and metastatic lymph nodes, in ovarian cancer patients.

METHODS

Fifty-seven FIGO stage IA-IV ovarian cancer patients, who underwent MDCT before primary surgery, were included in this study. Two radiologists evaluated the following imaging findings in consensus: the presence of nodular, plaque-like or infiltrative soft-tissue lesions in peritoneal fat or on the serosal surface; presence of ascites; parietal peritoneal thickening or enhancement; and small bowel wall thickening or distortion. We also evaluated the presence of lymph node metastases. To allow region-specific comparisons, the peritoneal cavity was divided into 13 regions and retroperitoneal lymph nodes were divided into 3 regions. Descriptive statistical data were thus obtained.

RESULTS

The MDCT sensitivity, specificity, positive predictive values, and negative predictive values were 45, 72, 46, and 72%, respectively, for detecting peritoneal seeding and 21, 90, 52, and 69%, respectively, for detecting lymph node metastasis.

CONCLUSIONS

MDCT is moderately accurate for detecting peritoneal metastasis and lymph node metastasis in ovarian cancer patients.

Для цитирования: Choi Hyuck Jae, Lim Myong Cheol, Bae Jaeman, Cho Kyoung-Sik, Jung Dae Chul, Kang Sokbom, Yoo Chong Woo, Seo Sang-Soo, Park Sang-Yoon. Region-based diagnostic performance of multidetector CT for detecting peritoneal seeding in ovarian cancer patients.. Archives of gynecology and obstetrics. 2010. DOI: 10.1007/s00404-010-1442-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.